IZ960 | 10 MHz – 3 GHz | Shielding Measurement System

In Stock

The IZ960 Shielding Measurement System is a portable, high-performance shielding effectiveness measurement solution designed for EMC, TEMPEST, and secure facility testing applications. Operating from 10 MHz to 3 GHz, the system provides accurate and reliable shielding measurements for rooms, chambers, military facilities, and embassies. Featuring synchronized transmitter and receiver operation, broadband antennas, and advanced IP960 measurement software, the IZ960 is ideal for compliance testing according to SDIP-29, IEEE Std 299, EN 50147-1, and related shielding standards.

General Specifications:

Device Type: Shielding Measurement System
Model Number: IZ960
Frequency Range: 10 MHz – 3 GHz
Measurement Type: Shielding Effectiveness (SE) Testing
Synchronization Method: Optical fibre or time synchronization
Receiver Type: Digital Receiver IZ225
Signal Generator: IZ240 High Power Generator
Included Antennas: IZ126-A03-28 and IZ126-A03-38 Broadband Antennas
Software: IP960 Measurement Software with HW Key
Interface Connectivity: Fibre optic and LAN communication
Impedance: 50 Ohms
Mounting Configuration: Carbon tripods included
Transport Configuration: PELI transport cases and accessories included
Standards Supported: SDIP-29, IEEE Std 299, EN 50147-1, IASG 07-01, NSA 65-6
Application Areas: EMC testing, TEMPEST testing, shielding effectiveness measurements, secure facility testing, military and embassy RF shielding validation

Category:
ENGINEERING DATA / IZ960

SPECIFICATION WORKSPACE

Technical data, resources and engineering actions for this exact catalog model.

IMPULSE IN-HOUSEIN STOCKLimited DATA COVERAGE
01
KEY SPECIFICATIONSCatalog values for IZ960
Frequency0.01–3 GHz
ENGINEERING USE: Confirm mechanical interface, environmental requirements, qualification level and application-specific limits before final design release. Published catalog values remain controlling where differences exist.

Description

Available Options

Option F02 Shielding Measurement System

Option F02

Extension to Shielding Measurement System 1 kHz to 18 GHz

Option F03 Shielding Measurement System

Option F03

Extension to Shielding Measurement System 1 kHz to 18 GHz

NEED HELP WITH THIS RF COMPONENT?Ask Impulse Sales

Get help with specifications or sourcing

Tell us what you need for IZ960 | 10 MHz - 3 GHz | Shielding Measurement System. Impulse Sales can follow up about specifications, matching products, or a quotation.

This is a one-to-one product-assistance request, not newsletter signup. Don't submit controlled or export-restricted technical details. See our privacy policy.