Narrow Band High Range Variable Attenuator – Voltage Controlled
General Specifications:
Frequency: 8-18GHz
Insertion Loss: 3.0dB Max
VSWR: 2:1 Max
Power Rating: +20dBm Operating (CW/PK), +30dBm Survival (CW/AVG)
Settling Time: 1μs
Attenuation Flatness:
10dB: ±0.5dB
20dB: ±1.2dB
40dB: ±2.2dB
60dB: ±2.5dB
80dB: ±2.5dB